One Way Slab Design to Eurocode 2

Design one way solid slabs to Eurocode 2 online. Quick Structural works out the moments, shear, reinforcement, curtailment and deflection check, and writes every step into a calculation report.

What is a one way slab?

A one way slab is supported on two opposite sides, or has a long side more than twice its short side, so it bends mainly across the short span. The main steel runs in that direction and lighter distribution steel runs across it. The slab is designed as a strip one metre wide.

What the slab tool covers

Quick Structural designs one way and two way solid slabs and Maxspan joist slabs. A quick calculation tool also converts slab loading into line loads on the supporting beams, and another converts a Maxspan slab into an equivalent solid slab.

Worked example: simply supported one way slab

A slab spans 4.5 m and is 200 mm thick. Finishes add 1.5 kN/m² and the imposed load is 3.0 kN/m². Concrete is C30/37, steel is fyk = 500 MPa, cover is 25 mm and the bars are 10 mm.

  1. Loads. Self weight = 25 × 0.20 = 5.0 kN/m². Permanent load gk = 5.0 + 1.5 = 6.5 kN/m². Imposed load qk = 3.0 kN/m².
  2. Ultimate load. n = 1.35 gk + 1.5 qk = 1.35 × 6.5 + 1.5 × 3.0 = 13.3 kN/m².
  3. Moment and shear for a 1 m strip. M = n L² / 8 = 13.3 × 4.5² / 8 = 33.6 kNm per metre. V = n L / 2 = 29.9 kN per metre.
  4. Effective depth. d = 200 − 25 − 5 = 170 mm.
  5. K factor. K = 33.6 × 10⁶ / (1000 × 170² × 30) = 0.039, so tension steel only is needed.
  6. Reinforcement. z is limited to 0.95 d = 161.5 mm, so As = 33.6 × 10⁶ / (0.87 × 500 × 161.5) = 479 mm² per metre. Provide H10 at 150 (524 mm² per metre).
  7. Shear. V = 29.9 kN per metre is well below the shear resistance of this slab without links, which is about 98 kN per metre.
  8. Deflection. Span to depth = 4500 / 170 = 26.5. The steel stress under service load is about 221 MPa, giving a modification factor of 310 / 221 = 1.40. The allowable ratio is about 20 × 1.40 = 28, which is above 26.5, so the check passes.

A 200 mm slab with H10 at 150 in the short direction works, with distribution steel across it. Try the same numbers in Quick Structural to see each check written out.

This is a simplified hand check for illustration. Quick Structural applies the complete Eurocode 2 procedure and writes out every step, so your own results may differ slightly.

Frequently asked questions

When is a slab treated as one way?

A slab is treated as one way when it spans between two opposite supports, or when its longer side is more than twice its shorter side.

Can Quick Structural also design two way slabs?

Yes. It designs one way and two way solid slabs, and Maxspan joist slabs.

Does it check deflection?

Yes. The deflection check uses the Eurocode 2 span to effective depth method and is shown in the report.

Can I get a quick starting thickness?

Yes. Use the preliminary slab sizing tool to get a starting thickness from the span, support conditions and imposed load.

Can I rely on the results for a real building?

Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.