Solid Slab Design to Eurocode 2

Design one way and two way solid slabs in your browser. Quick Structural works out the loads, the moments in each direction, the top and bottom reinforcement, and the crack control, shear and deflection checks, and writes every step into a report.

What the solid slab tool does

Enter the panel size, thickness, loads and edge conditions. The tool takes the moments from the Eurocode 2 coefficients for the panel type, designs the bottom layers (B1 and B2) and top layers (T1 and T2), and then checks crack control, shear and deflection.

Example: interior two way panel

These are the inputs and key results from the report shown below. Slab Panel 1 is a 160 mm thick interior panel with equal spans, so it spans in two directions. All of its checks pass.

Panel and thickness5.0 m by 5.0 m interior panel, 160 mm thick, aspect ratio 1.0
Materialsfck = 25 N/mm², fyk = 500 N/mm², cover 25 mm
LoadsDead load 6.2 kN/m² (self weight 4.0, finishes 1.0, ceiling and services 1.2), imposed load 1.2 kN/m²
Ultimate loadn = 10.17 kN/m²
Sagging moments6.10 kNm/m in each direction
Hogging moments8.14 kNm/m and 7.88 kNm/m
Bottom steelB1 172 mm²/m required, H12 at 200 provided (565 mm²/m). B2 156 mm²/m required, H12 at 300 provided (377 mm²/m)
Top steelT1 172 mm²/m, H12 at 200. T2 168 mm²/m, H12 at 300
Crack controlProvided spacing is within the allowable spacing
ShearDesign shear 16.78 kN/m against a resistance of 68.77 kN/m without links
DeflectionActual span to depth 38.76, permitted 40.0

A real solid slab design report

This is the report exactly as Quick Structural produces it. The first pages are shown here. Use the button to read the whole report, including the crack control tables and the shear and deflection checks.

Open the full report as a PDF

Frequently asked questions

Can it design one way slabs as well as two way slabs?

Yes. The tool designs one way and two way solid slabs. The panel type and the ratio of the long to the short span decide how the moments are found.

Where do the moments come from?

They come from the Eurocode 2 moment coefficients for the panel type, applied to the ultimate load and the short span.

Does it check deflection and cracking?

Yes. The report includes the bar spacing check for crack control and the span to effective depth check for deflection.

Is there a lighter slab system?

Yes. See the Maxspan slab design for ribbed slabs built with Maxspan units.

Can I rely on the results for a real building?

Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.

Related guides

Free tools

Sign up to design a slab