Rectangular Beam Design to Eurocode 2

Design rectangular concrete beams for bending and shear. Quick Structural gives separate reports for a beam span (sagging) and a beam support (hogging), each with every step written out.

What the rectangular beam tool does

The span report designs the bottom steel for the sagging moment and then checks deflection and shear. The support report designs the top steel for the hogging moment. Both start from the section size, cover and the assumed bar and link sizes.

Example: 230 by 450 mm beam

These are the inputs and key results from the two reports shown below. They use the same section and moment. This example report includes checks that fail, which Quick Structural flags clearly so you know exactly what to change.

Section230 mm wide, 450 mm deep, 4.0 m span, cover 30 mm, assumed 16 mm bars and 8 mm links
Materialsfck = 25 N/mm², fyk = 500 N/mm²
Effective depth404 mm
Design moment150 kNm (sagging for the span, hogging for the support)
BendingK = 0.16, below 0.167, so singly reinforced. Lever arm 335 mm
Steel1028 mm² required, minimum 124 mm², maximum 4140 mm²
Steel provided2 H16 plus 1 extra H16 gives 603 mm², which the report flags as inadequate
DeflectionActual span to depth 9.9 against 12.66 permitted, reduced because the steel provided is below the steel required
ShearDesign shear 146 kN against 48.09 kN for the concrete alone, so links are needed
Shear linksStrut angle 22 degrees. H8 links at 150 mm give a link resistance of 263.99 kN, adequate

A real rectangular beam span design report

This is the report for the beam span, exactly as Quick Structural produces it. The first pages are shown here. Use the button to read all six pages.

Open the full report as a PDF

A real rectangular beam support design report

This is the report for the beam support, where the moment is hogging and the steel goes at the top.

Open the full report as a PDF

Frequently asked questions

What is the difference between the span and the support report?

The span report designs the bottom steel for the sagging moment and also checks deflection and shear. The support report designs the top steel for the hogging moment.

What does singly reinforced mean?

The section needs steel in the tension zone only. When K is above the limit of 0.167, compression steel is needed too.

How are the shear links chosen?

The report checks the concrete resistance, picks a strut angle, works out the links needed and checks the maximum spacing.

Can I design T and L beams?

Yes. See the flange beam design for beams with an effective flange width.

Can I rely on the results for a real building?

Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.

Related guides

Free tools

Sign up to design a beam