Isolated Footing Design Calculator

Size and design isolated pad footings to Eurocode 2. Quick Structural checks soil pressure, bending, one way shear and punching shear, then gives you a full calculation report.

What an isolated footing design involves

An isolated pad footing carries one column and spreads its load into the soil. The plan size is set first, so that the bearing pressure under service loads stays below the allowable value from the geotechnical report. The thickness and reinforcement are then found from bending, one way shear and punching shear around the column.

Example: isolated footing under a column

These are the inputs and key results from the report shown below. The trial footing in this report is too small for the load, so Quick Structural flags the footing area, a steel check and the shear checks.

Column and loads300 mm by 300 mm column, dead load 500 kN, imposed load 150 kN, service load 650 kN, ultimate load 900 kN
Soil and trial footingAllowable bearing pressure 200 kN/m², trial footing 1.0 m by 1.0 m by 300 mm
Footing size3.29 m² required, which is 1.81 m square. The trial footing is flagged as too small
Design moment55.12 kNm per metre in each direction
Bottom steel, direction B1551 mm²/m required, H16 at 200 provided (1005 mm²/m), crack control passes
Bottom steel, direction B2585 mm²/m required, H12 at 200 provided (565 mm²/m), flagged as inadequate with a crack control fail
Face shear3.67 N/mm² against a limit of 4.5 N/mm²
Direct shearAlong the length: 0.402 against 0.50 N/mm², passes. Across the width: 0.482 against 0.472 N/mm², fails
Punching shearCannot be checked, because the control perimeter lies outside the trial footing

A real isolated footing design report

This is the report exactly as Quick Structural produces it. The first pages are shown here. Use the button to read all seven pages.

Open the full report as a PDF

Frequently asked questions

Does it design footings that carry a moment as well as axial load?

Yes. Isolated pad footings can be designed for axial load and moment, including the soil pressure under each case.

Does it check punching shear?

Yes. Punching shear is checked around the column along with one way shear.

Can it suggest a starting size?

Yes. The footing sizing tool gives preliminary plan dimensions and thickness from the allowable soil bearing pressure.

What about two columns close together?

Use the combined footing design, which handles two or more columns.

Can I rely on the results for a real building?

Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.