Isolated Footing Design Calculator
Size and design isolated pad footings to Eurocode 2. Quick Structural checks soil pressure, bending, one way shear and punching shear, then gives you a full calculation report.
What an isolated footing design involves
An isolated pad footing carries one column and spreads its load into the soil. The plan size is set first, so that the bearing pressure under service loads stays below the allowable value from the geotechnical report. The thickness and reinforcement are then found from bending, one way shear and punching shear around the column.
- Axial load and moment from the column
- Soil bearing pressure under service and ultimate loads
- Bending reinforcement in both directions
- One way shear and punching shear checks
- Preliminary plan size and thickness from the allowable bearing pressure
Example: isolated footing under a column
These are the inputs and key results from the report shown below. The trial footing in this report is too small for the load, so Quick Structural flags the footing area, a steel check and the shear checks.
| Column and loads | 300 mm by 300 mm column, dead load 500 kN, imposed load 150 kN, service load 650 kN, ultimate load 900 kN |
|---|---|
| Soil and trial footing | Allowable bearing pressure 200 kN/m², trial footing 1.0 m by 1.0 m by 300 mm |
| Footing size | 3.29 m² required, which is 1.81 m square. The trial footing is flagged as too small |
| Design moment | 55.12 kNm per metre in each direction |
| Bottom steel, direction B1 | 551 mm²/m required, H16 at 200 provided (1005 mm²/m), crack control passes |
| Bottom steel, direction B2 | 585 mm²/m required, H12 at 200 provided (565 mm²/m), flagged as inadequate with a crack control fail |
| Face shear | 3.67 N/mm² against a limit of 4.5 N/mm² |
| Direct shear | Along the length: 0.402 against 0.50 N/mm², passes. Across the width: 0.482 against 0.472 N/mm², fails |
| Punching shear | Cannot be checked, because the control perimeter lies outside the trial footing |
A real isolated footing design report
This is the report exactly as Quick Structural produces it. The first pages are shown here. Use the button to read all seven pages.
Frequently asked questions
Does it design footings that carry a moment as well as axial load?
Yes. Isolated pad footings can be designed for axial load and moment, including the soil pressure under each case.
Does it check punching shear?
Yes. Punching shear is checked around the column along with one way shear.
Can it suggest a starting size?
Yes. The footing sizing tool gives preliminary plan dimensions and thickness from the allowable soil bearing pressure.
What about two columns close together?
Use the combined footing design, which handles two or more columns.
Can I rely on the results for a real building?
Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.
Related guides
- Design Maxspan Slabs
- Design Solid Slabs
- Design Rectangular Beams
- Design Flange Beams
- Design Uniaxial Columns
- Design Biaxial Columns
- Design Combined Footings
- Design Staircases
- All products
- Pricing