Uniaxial Column Design to Eurocode 2

Design a column that carries an axial load with a moment about one axis. Quick Structural checks slenderness, adds the second order moments when they matter, finds the reinforcement and checks the biaxial effect of the imperfections.

What the uniaxial column tool does

The column is checked for slenderness about both axes. A slender column gets second order moments, and every column gets the minimum eccentricity and the effect of imperfections. The reinforcement comes from the design charts and is then checked against the minimum and maximum limits.

Example: slender column under axial load and bending

These are the inputs and key results from the report shown below. This example report includes checks that fail, which Quick Structural flags clearly so you know exactly what to change.

Column275 mm by 275 mm, cover 35 mm, 20 mm bars and 8 mm links
Materialsfck = 25 N/mm², fyk = 500 N/mm²
Height and effective length7.0 m storey height, effective length factor 0.59, effective length 4130 mm
LoadsDesign axial load 696 kN, end moments −27.5 and 55.0 kNm about the y axis
Slenderness52.0 against a limit of 42.0 about the y axis, so the column is slender
Second order moment20.94 kNm
Design moments62.19 kNm about the y axis and 28.13 kNm about the z axis
Reinforcement1059 mm² required. 4 H20 provided (1257 mm²), with H8 links at 275 mm and 165 mm near the ends
Curvature factorKr assumed 0.8, calculated 0.78, so the assumption holds
Biaxial checkThe sum of the moment ratios is 1.226 against a limit of 1.0, so the report flags a fail

A real uniaxial column design report

This is the report exactly as Quick Structural produces it. The first pages are shown here. Use the button to read all seven pages.

Open the full report as a PDF

Frequently asked questions

When does a column need second order moments?

When it is slender, meaning its slenderness ratio is above the limit worked out from the axial load and the end moments.

What is the minimum eccentricity?

Eurocode 2 requires a design moment of at least the axial load times the larger of h / 30 or 20 mm. The report applies it automatically.

Where does the steel area come from?

From the column design charts, using the axial load and moment ratios. The result is then checked against the minimum and maximum steel limits.

What if both axes carry moments?

See the biaxial column design.

Can I rely on the results for a real building?

Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.

Related guides