T and L Beam Design to Eurocode 2
Design flanged concrete beams in your browser. Quick Structural finds the effective flange width, checks where the neutral axis lies, designs the web steel and the transverse flange steel, and checks deflection and shear.
What the flange beam tool does
For a T or L beam the slab acts as a flange, but only part of it works with the web. The tool works out the effective flange width from the span and the slab clear spans, then designs the beam as a rectangular section of that width when the neutral axis stays inside the flange.
- Effective flange width for each side of the web
- Neutral axis check against the flange thickness
- Web steel for bending, with minimum and maximum limits
- Longitudinal shear at the flange and web junction, and the transverse flange steel
- Deflection with the flange modification factor, and shear links
Example: T beam with a 5.0 m span
These are the inputs and key results from the report shown below. This example report includes checks that fail, which Quick Structural flags clearly so you know exactly what to change.
| Section | 250 mm web, 500 mm deep, 150 mm flange, 5.0 m span, cover 30 mm, 16 mm bars and 8 mm links |
|---|---|
| Materials | fck = 30 N/mm², fyk = 500 N/mm² |
| Effective flange width | beff = 1700 mm, from 725 mm either side of the web |
| Effective depth | 454 mm |
| Design moment | 200 kNm |
| Bending | K = 0.019, singly reinforced. Neutral axis 45 mm deep, inside the 150 mm flange |
| Web steel | 1066 mm² required, minimum 171 mm², maximum 5000 mm² |
| Steel provided | 2 H16 plus 1 extra H16 gives 603 mm², which the report flags as inadequate |
| Flange steel | Longitudinal shear stress 0.619 N/mm². H12 at 250 provided (452 mm²/m) |
| Deflection | Actual span to depth 11.01 against 7.15 permitted, so the check fails |
| Shear | Design shear 146 kN against 57.03 kN for the concrete alone. H8 links at 150 mm give 296.67 kN, adequate |
A real flange beam design report
This is the report exactly as Quick Structural produces it. The first pages are shown here. Use the button to read all nine pages.
Frequently asked questions
How is the effective flange width found?
From the distance between points of zero moment and the clear spans of the slabs either side, using the Eurocode 2 rules. A quick calculation tool also gives you the flange width on its own.
What happens if the neutral axis falls below the flange?
The beam is then designed as a true T section rather than a rectangular section of width beff.
Why is there steel across the flange?
The flange and web must act together, so the shear at their junction is carried by transverse steel in the slab.
Can I design a simple rectangular beam?
Yes. See the rectangular beam design for spans and supports.
Can I rely on the results for a real building?
Quick Structural is a design aid. Every design should be checked and approved by a qualified, registered engineer before it is used for construction.
Related guides
- Design Maxspan Slabs
- Design Solid Slabs
- Design Rectangular Beams
- Design Uniaxial Columns
- Design Biaxial Columns
- Design Isolated Pad Footings
- Design Combined Footings
- Design Staircases
- All products
- Pricing